Product Description

125mm VIT-Smooth 45° / 135° Vitreous Enamel Elbow with Access Door

Model: 67-125-041

The 125mm VIT-Smooth 45° elbow with access door creates an angled change of direction within a compatible single-wall connecting flue. Its built-in door also provides access for inspecting and sweeping the inside of the pipe.

This component may be described as either a 45-degree or 135-degree elbow, depending on how the angle is measured. In practical terms, it changes the direction of a straight flue route by 45 degrees.

Made from 1.2mm zero-carbon steel, the elbow has a powder vitreous enamel coating on its internal and external surfaces. Therefore, it provides a durable, heat-resistant fitting with a smooth matt black finish.

125mm 45° Elbow with Door Features

  • 125mm (5-inch) nominal flue diameter
  • 45° / 135° elbow configuration
  • Built-in access door for inspection and sweeping
  • Manufacturer model number: 67-125-041
  • Designed for compatible VIT-Smooth connecting flues
  • Helps create a flue offset or change of direction
  • Smoothly finished welded construction
  • Made from 1.2mm zero-carbon steel
  • Approximately 0.2mm powder vitreous enamel coating
  • Approximately 1.4mm total thickness, including enamel
  • Internal and external enamel finish
  • Heat-resistant matt black colour
  • Friction-fit connections
  • Suitable for compatible gas, oil and solid-fuel appliances
  • Maximum continuous operating temperature: 600°C
  • Product designation: EN 1856-2 T600 N1 Vm L80120 G375
  • Minimum declared distance from combustible materials: 375mm
  • 12-year warranty, subject to the manufacturer’s terms

Technical Specification

  • Product type: Single-wall flue elbow with access door
  • Nominal diameter: 125mm (5 inches)
  • Angle: 45° / 135°
  • Access: Built-in inspection and sweeping door
  • Material: Zero-carbon steel
  • Steel thickness: 1.2mm
  • Enamel thickness: Approximately 0.2mm
  • Total thickness: Approximately 1.4mm
  • Coating: Powder vitreous enamel
  • Colour: Matt black
  • Joint type: Friction fit
  • Temperature classification: T600
  • Product standard: EN 1856-2
  • Distance from combustibles: 375mm
  • Warranty: 12 years, subject to terms
  • Model: 67-125-041

Why Is It Called a 45° / 135° Elbow?

Flue fittings may describe a bend by either its change from a straight pipe or the internal angle created by the fitting. Therefore, the same component may appear as a 45-degree or 135-degree elbow in product descriptions and technical drawings.

In practical terms, this elbow redirects the pipe by 45 degrees. Always check the manufacturer’s dimensions when calculating the exact offset and installed height.

What Is a 45° Flue Elbow Used For?

This elbow allows a compatible 125mm connecting flue to change direction. For example, an installer may use it to align the pipe with an offset chimney opening or avoid a suitable non-combustible obstruction.

Two 45-degree elbows may be used to create an offset when the appliance instructions and chimney design permit it. The final displacement depends on the orientation of the elbows and the pipe length fitted between them.

The installer should keep the complete route as short and direct as reasonably possible. Every change of direction creates resistance to flue-gas flow and may affect chimney draught.

What Is the Access Door Used For?

The built-in access door allows a competent person or chimney sweep to inspect and clean the inside of the elbow. This can prove particularly useful because soot and other deposits may collect near a change of direction.

Access at the bend can also make it easier to guide suitable sweeping equipment through the offset. However, the installer must confirm that every relevant section of the complete chimney remains accessible.

The door provides local access only. It does not guarantee that the entire chimney can be swept from that position.

Planning a Flue Offset

Before ordering, calculate the required horizontal displacement and vertical rise using the relevant dimensional drawing. Do not rely on the nominal 45-degree angle alone.

If two elbows form an offset, ensure the pipe between them remains correctly supported. The completed arrangement must not place excessive sideways loading on the joints or appliance outlet.

The flue route must also provide suitable sweeping access. In some installations, an elbow with a door offers a practical advantage over a standard closed fitting.

Why Choose VIT-Smooth?

VIT-Smooth combines robust steel construction with a carefully finished vitreous enamel surface. The welds are designed to remain discreet, creating a clean and professional appearance.

Furthermore, the internal and external enamel coating helps protect the steel against heat, combustion gases and corrosive deposits. Its matt black finish complements many traditional and contemporary stoves.

Suitable Applications

  • Compatible wood-burning stoves
  • Compatible multifuel stoves
  • Suitable gas heating appliances
  • Suitable oil-fired appliances
  • 125mm VIT-Smooth connecting-flue systems
  • Offsets within a visible stove-pipe run
  • Installations requiring access at a change of direction
  • Connections leading towards a suitable chimney system

Positioning the Access Door

Install the elbow so the access door remains visible, unobstructed and easy to reach. Allow enough space for the door to open and for a competent person to insert suitable inspection or sweeping equipment.

Do not position the door against a wall, register plate, bracket or another flue component. In addition, do not install it within a concealed space or permanent enclosure.

Rotating the elbow changes both the offset direction and the orientation of the access door. Therefore, the installer should consider the door position when setting out the complete flue route.

Access-Door Safety

The access door must remain fully closed and correctly secured whenever the appliance operates. Never light or use the appliance with the door open, loose, damaged or missing.

Allow the appliance and chimney to cool completely before opening the door. Hot gases, soot and other combustion deposits may cause burns or create a fire risk.

After inspection or sweeping, clean the closing surfaces and check that the door returns to its correct position. Replace any damaged closing or sealing component before using the appliance again.

Installation Direction

Install the elbow with the smaller or male end pointing downwards towards the appliance. This orientation helps keep condensate and combustion deposits inside the flue system.

Ensure both connections engage fully and remain mechanically secure. Do not reverse the elbow or force together products with incompatible joint profiles.

Jointing and Sealing

Compatible VIT-Smooth components use close-fitting connections. Consequently, jointing compound is not automatically required at every correctly assembled joint.

However, the appliance and flue manufacturers determine the approved sealing method. Only use suitable fire cement, high-temperature sealant or another jointing product when the current instructions permit it.

Do not seal the access door permanently or apply an unsuitable material around its opening. The door must remain functional and removable for future inspection and sweeping.

Installation and Safety Information

Use VIT-Smooth only as a single-wall connecting flue between a compatible appliance and a suitable chimney, flexible liner or insulated twin-wall system. Never use this elbow to pass through a wall, ceiling, roof or concealed void.

Maintain at least the declared 375mm distance from combustible materials. These may include timber, furniture, combustible wall finishes and some plasterboard constructions. Follow any greater clearance required by the appliance manufacturer.

The elbow must remain exposed and accessible. Do not box it in, conceal the access door or position it where future maintenance becomes impossible.

The elbow must not support the weight of a flexible liner or chimney system. Use suitable system supports to prevent damaging loads on the joints and appliance outlet.

A competent installer should design and fit the complete flue. For solid-fuel work, use a suitably qualified installer, such as a HETAS-registered installer, or notify Building Control where required.

Finally, follow the appliance instructions, current VIT-Smooth guidance and applicable Building Regulations. The appliance manufacturer’s instructions determine the permitted diameter, route and number of bends.

Inspection and Maintenance

A competent person should inspect and clean the complete chimney regularly. The required frequency depends on the appliance, fuel, level of use and chimney condition.

The built-in access door simplifies local inspection and sweeping near the bend. Nevertheless, the chimney sweep must confirm that their equipment can reach every required section of the system.

Use cleaning equipment that will not damage the vitreous enamel. During maintenance, inspect the door, closure, elbow and adjoining joints for movement, corrosion, distortion or enamel damage.

Product Guide

Why Buy from SNH Tradecentre?

  • Competitive prices: We aim to offer excellent value across our flue and chimney range.
  • Helpful advice: Our team can help you compare elbows with and without access doors.
  • Genuine products: Order from an established plumbing and heating merchant.
  • Collection available: Collect eligible in-stock products from our Birchington trade counter.
  • UK delivery: Choose from the available delivery services at checkout.
  • Trade and public welcome: We supply installers, homeowners, landlords and property professionals.

Need help selecting the correct flue elbow? Call SNH Tradecentre on 01843 842727 before ordering. If possible, have the appliance model, flue diameter and proposed offset measurements ready.

Read reviews from SNH Tradecentre customers on Google

Frequently Asked Questions

What diameter is this VIT-Smooth elbow?

It has a nominal diameter of 125mm, equivalent to approximately five inches. It is designed for compatible 125mm VIT-Smooth components.

Is this a 45-degree or 135-degree elbow?

Both descriptions refer to the same general fitting. It changes the direction of the flue by 45 degrees, while its internal angle may be described as 135 degrees.

What is the access door used for?

It provides access for inspecting and sweeping the inside of the elbow, particularly around the change of direction where deposits may collect.

Can I operate the appliance with the door open?

No. The door must remain correctly closed and secured whenever the appliance operates.

Can the access door face a wall?

No. Install the elbow so the door remains accessible and has sufficient space to open. A chimney sweep must be able to use suitable cleaning equipment through it.

Can two 45-degree elbows create an offset?

Yes, when the appliance instructions and chimney design permit the arrangement. The final displacement depends on the elbows’ dimensions and the pipe length between them.

Does the door guarantee that the entire chimney can be swept?

No. It provides local access only. The installer and chimney sweep must confirm that all relevant parts of the complete system remain reachable.

Can I use this elbow with a wood-burning stove?

It may suit a compatible wood-burning or multifuel stove. However, the appliance manufacturer must permit the 125mm diameter and proposed flue arrangement.

Which way up should the elbow be installed?

The smaller or male end should point downwards towards the appliance. This helps keep condensate and deposits inside the flue system.

What is the maximum operating temperature?

The elbow carries a T600 classification. Therefore, its maximum continuous operating temperature is 600°C. Always observe any lower limit specified by the appliance manufacturer.

Can this elbow pass through a wall or ceiling?

No. This is a single-wall connecting-flue component. It must not pass through walls, ceilings, roofs or concealed spaces.

How far must it be from combustible materials?

The product designation declares a minimum distance of 375mm from combustible materials. However, the installer must observe any greater clearance required by the appliance or current regulations.

Does the joint require fire cement?

Not automatically. Compatible VIT-Smooth components use close-fitting joints. Only apply an approved jointing material when the current appliance and flue instructions require or permit it.

Who should install this flue elbow?

A competent installer should fit it as part of a properly designed chimney system. For solid-fuel installations, consider using a HETAS-registered installer or arranging Building Control notification where required.

Manufacturers may update specifications, product designs and installation guidance. Therefore, check the latest VIT-Smooth literature and confirm the required offset and door position before ordering.

Additional Information

Weight 999 g
Manufacturer

Mi Flue

Brand

MPN

67-125-041

SKU

67-125-041

Unit Quantity

1

EAN

5060795860390

Warranty

12 Year Warranty

Shipping

Medium Item

Range

Vitreous Enamel 5 inch

condition

new

Woocategory1

Flues & Fittings

Woocategory3

Woocategory2

Vitreous Enamel Single Wall Flue

Country/Region of Manufacture

United Kingdom

Colour

Matt Black

Width

5 inch

Hetas Approved

Yes

Length

0

Standards

EN1856-2 T600 N1 Vm L80120 G375

Outer Material

1.2mm thick

Distance From Combustibles

375mm

 

 

 

 

 

 

Local Pick Up           Free

England & Wales    £3.48

Scotland From        £3.48

Unfortunately we do not deliver to Ireland, Scottish Islands and Isle Of Wight.

If you need more infomation regarding delivery, please call 01843 842727 Mon to Fri 8am to 5pm.