Ideal Logic Air 250L Heat Pump Pre Plumbed c/w Buffer 1 Zone

The Ideal Logic Air 250L Heat Pump Pre-Plumbed Cylinder with Integrated Buffer combines approximately 239 litres of domestic hot-water storage with a separate 63.5-litre heating buffer. Designed for compatible single-zone air source heat pump systems, it includes the Ideal CBOX, a 3kW immersion heater and key system components.

£2,415.83 £2,899.00 (inc vat)

In stock

Product Description

Ideal Logic Air 250L Heat Pump Pre-Plumbed Cylinder with Buffer 1 Zone CBOX

Model: 236210

PLEASE NOTE: We can only deliver this product to Mainland England addresses. Please read the installation instructions and confirm system suitability before ordering.

The Ideal Logic Air 250L Heat Pump Pre-Plumbed Cylinder with Integrated Buffer combines domestic hot-water storage, heating-system water volume and key heat pump controls in one practical unit.

Ideal designed this cylinder for use with compatible air source heat pump systems. It provides approximately 239 litres of domestic hot-water storage and includes a separate 63.5-litre integrated buffer for the primary heating circuit.

The integrated buffer increases the volume of water within the heating system. Therefore, it can support steady water flow and help reduce frequent heat pump cycling when the system has been designed correctly.

Meanwhile, the large 2.5m² internal heat exchanger supports effective heat transfer at the lower flow temperatures commonly used by heat pumps. The supplied CBOX also provides a central point for connecting the system controls, pumps, valves and temperature sensors.

This model supports a single-zone heating system. It may suit properties where the radiators or underfloor heating operate as one controlled heating area.

Important: This listing includes the pre-plumbed cylinder, integrated buffer and listed system components. It does not include the outdoor air source heat pump unless the product offer clearly states otherwise.

Installation Guide and Product Information

Ideal Logic Air 250L Cylinder Features

  • Pre-plumbed heat pump cylinder with integrated buffer
  • Designed for compatible air source heat pump systems
  • Suitable for a single-zone heating system
  • Nominal cylinder size of 250 litres
  • Actual domestic hot-water capacity of approximately 239 litres
  • Integrated 63.5-litre heating buffer
  • Large 2.5m² primary heat exchanger
  • Approximately 26.56-minute heat-up time under the manufacturer’s test conditions
  • Built-in 3kW immersion heater
  • Secondary return connection
  • Energy efficiency class B
  • Approximately 62W standing heat loss
  • Includes Ideal CBOX controls
  • Includes key valves, pumps and temperature sensors
  • Pre-plumbed and pre-wired construction
  • 25-year cylinder vessel warranty, subject to Ideal’s terms
  • Two-year warranty on other supplied components, subject to Ideal’s terms
  • Ideal product code 236210

Key Features and Benefits

  • Integrated 63.5L Buffer: Adds water volume to the heating circuit and can help the heat pump complete longer, steadier operating cycles.
  • Pre-Plumbed Design: Factory-fitted pipework and components can reduce installation time and create a neater system.
  • Heat Pump Heat Exchanger: The 2.5m² primary coil supports efficient heat transfer at typical heat pump temperatures.
  • Single-Zone Control: Designed for a property that operates its heating as one controlled area.
  • Ideal CBOX Included: Provides a central connection point for the pumps, valves, thermistors and other controls.
  • 239L Actual Capacity: Provides stored mains-pressure hot water for compatible showers, baths and taps.
  • Secondary Return: Supports a correctly designed domestic hot-water circulation system.
  • Immersion Heater: The fitted 3kW immersion provides an additional electric heat source.

Technical Specification

  • Manufacturer: Ideal Heating
  • Range: Logic Air
  • Product Code: 236210
  • Cylinder Model: IDEPLUHP250DUOPPSZ
  • Product Type: Pre-plumbed heat pump cylinder with integrated buffer
  • Heating Zones: One
  • Nominal Cylinder Size: 250 litres
  • Actual DHW Capacity: Approximately 239 litres
  • Integrated Buffer Capacity: 63.5 litres
  • Primary Heat Exchanger: 2.5m²
  • Heat-Up Time: Approximately 26.56 minutes under the manufacturer’s stated test conditions
  • Immersion Heater: 3kW
  • Secondary Return: Yes
  • Energy Efficiency Class: B
  • Heat Loss: Approximately 62W
  • Standing Heat Loss: Approximately 1.49kWh per 24 hours
  • Pressure-Reducing Valve Setting: 3 bar
  • Expansion Relief Valve Setting: 4.5 bar
  • Temperature and Pressure Relief Valve: 95°C / 6 bar
  • Vessel Warranty: 25 years, subject to Ideal’s terms and conditions
  • Component Warranty: Two years, subject to Ideal’s terms and conditions

Dimensions and Weight

  • Overall Height: 1908mm
  • Overall Width: 705mm
  • Overall Depth: 780mm
  • Cylinder Diameter: 630mm
  • Cylinder Body Height: 1829mm
  • Empty Weight: 77kg
  • Approximate Full Weight: 379kg

Before ordering, measure the installation area carefully. Allow enough space for the cylinder, connected pipework, electrical connections and future servicing.

The supporting floor must also carry the cylinder’s full operating weight of approximately 379kg. Therefore, the installer should check the proposed location before delivery.

What Comes with the Cylinder?

  • 1 x Ideal Logic Air 250L pre-plumbed unvented cylinder
  • 1 x integrated 63.5-litre buffer tank
  • 1 x 3kW immersion heater
  • 1 x Ideal control box
  • 1 x heat pump system filter
  • 1 x domestic hot-water three-port valve
  • 1 x pressure and temperature relief valve
  • 1 x high-temperature cut-out
  • 1 x expansion vessel
  • 1 x pressure gauge
  • Automatic air vent or vents
  • Isolation valves
  • Circulation pump or pumps
  • Flow and return thermistors
  • Domestic hot-water thermistor
  • Outdoor temperature sensor

Additional pipework, valves, electrical equipment and fittings may be required. Therefore, the installer should check the complete system design and the latest Ideal instructions before installation.

How Does the Integrated Buffer Work?

The integrated buffer stores primary heating water rather than domestic drinking water. It adds 63.5 litres to the heating circuit and helps maintain stable water flow through compatible heat pump systems.

As a result, the heat pump may run for longer periods instead of starting and stopping frequently. Longer operating cycles can support stable system performance when the heating demand falls below the heat pump’s minimum output.

The buffer can also help separate the heat pump circuit from the heating circuit hydraulically. However, the installer must design, balance and commission the complete system correctly.

How Does the Heat Pump Cylinder Work?

The air source heat pump transfers energy into the stored domestic hot water through the cylinder’s internal primary coil. Because heat pumps often use lower flow temperatures than gas or oil boilers, this cylinder includes a large 2.5m² heat exchanger.

Cold mains water enters the unvented cylinder and replaces the hot water used at showers, baths and taps. Therefore, the property does not need a traditional cold-water storage tank in the loft.

However, hot-water performance depends on the incoming mains water pressure and flow. A qualified installer should test both before recommending the cylinder.

What Does CBOX Mean?

CBOX refers to the supplied Ideal control box. It provides a central point for connecting the system pumps, valves, thermistors and other electrical controls.

The pre-wired and pre-plumbed arrangement can reduce work on site. In addition, it helps create a cleaner installation with components designed to operate together.

What Does Single Zone Mean?

A single-zone heating system controls the property as one heating area. For example, one time and temperature schedule may control all compatible radiators or underfloor heating circuits.

This arrangement can suit homes that do not need separate upstairs and downstairs heating control. However, the installer must still calculate the required flow rates and confirm that the selected emitters suit the heat pump.

Is a 250L Heat Pump Cylinder Suitable for My Home?

A cylinder in this size range may suit medium to larger homes with regular demand from several hot-water outlets. However, the correct cylinder size depends on much more than the number of bedrooms.

A qualified system designer should consider:

  • The number of people living in the property
  • The number of bathrooms, showers and baths
  • How often the household uses hot water
  • The size and type of baths
  • The incoming mains pressure and flow
  • The selected heat pump output
  • The required hot-water recovery time
  • The property’s calculated heat loss
  • The heating emitters and control arrangement

For this reason, always ask the system designer or installer to confirm the required cylinder and buffer capacity before ordering.

Installation Requirements

A suitably trained heating engineer must design, install and commission this cylinder. The installer must also hold the required qualification or recognised competence for unvented hot-water systems.

The installation must follow current Building Regulations, the latest Ideal instructions and the approved heat pump system design. In addition, a qualified electrician must complete the electrical connections.

The installer should check the cylinder size, system pressure, incoming mains supply, discharge pipework, heat pump compatibility, flow rates and control arrangement before starting work.

Why Choose the Ideal Logic Air 250L Cylinder?

The Ideal Logic Air 250L package combines hot-water storage, a heating buffer and key system controls in one coordinated product. Therefore, it can reduce the number of separate components required within the installation.

The large heat exchanger supports heat pump operation, while the integrated buffer adds valuable system volume. Meanwhile, the factory-fitted controls and components can save installation time and create a neater finish.

This model also offers a useful 239-litre domestic hot-water capacity. As a result, it can support properties with greater hot-water demand when a qualified installer sizes the system correctly.

Why Buy from SNH Tradecentre?

  • Competitive prices on Ideal heat pump products
  • Helpful product and technical advice
  • Genuine products from established manufacturers
  • Clear specifications to help you order correctly
  • Delivery available to eligible Mainland England addresses
  • Trade and public customers welcome
  • Independent UK plumbing and heating merchant
  • Collection available from our Birchington, Kent trade counter

Ideal Heating may update product specifications, package contents and warranty conditions without notice. Check the latest manufacturer’s information and confirm suitability with a qualified system designer before ordering.

Additional Information

gtin

5022142362100

Manufacturer

Ideal

Brand

MPN

236210

SKU

236210

Unit Quantity

1

EAN

5022142362100

Warranty

25 Year Warranty

Shipping

Bulk Delivery Charge

Range

Heat Pump/Buffer

condition

new

Woocategory1

Heating & Cooling

Woocategory3

Woocategory2

Hot Water Cylinders

Country/Region of Manufacture

United Kingdom

Style

Heat Pump / Buffer Culinder

Width

780

Height

ccp_Type

Heat Pump

Material

Stainless Steel

Modified Item

No

Custom Bundle

No

Mounting

Floor

Mount Type

Floor Standing

Litres

201 – 250

Heating System

Storage Tank

Manufacturer Warranty

25 Year Warranty

We will send this item out by Pallet Service for you. Once you have placed your order we will contact you by phone to arrange a delivery day.

Local Pick Up Free

Local Delivery Free (on our own transport)

England & Wales Free

Scotland £165.00

Unfortunately we do not deliver to Ireland, Scottish Islands or above Glasgow and Isle Of Wight.

If you need more infomation regarding delivery, please call 01843 842727 Mon to Fri 8am to 5pm.